№ | The name of the coating process | The maximum working volume of the bath, mm | Note |
---|---|---|---|
1 | Zinc-plating | 400×1600×300 | |
2 | Chromium plating | 400×1600×300 | Molds do not chrome. |
3 | Tin plating | 300×700×400 | |
4 | Copper plating | 300×500×400 | Need special equipment |
5 | Nickel plating | 300×700×400 | |
6 | Phosphating | 500×1800×600 | |
7 | Chemical oxidation | 600×1800×600 | |
8 | Blueing | 250×300×300 | |
9 | Passivation of stainless steel | 400×800×500 | |
10 | Chromic acid anodizing | 300×700×400 | |
11 | Anodizing | 300x700x400 300×500×400 300×500×400 300×700×400 | |
12 | Silvering | 300×2000×300 | Waveguide pipes(up to 2000mm.) and other details. Silvering of copper, brass,steel, titanium(100×200×100) |
Electroplated coating:
Weight, number of parts and other specifications can be discussed.
Paintwork:
Drawing paint and varnish covering, and coloring of devices, details, knots enamel PF-218, PF-115, EP-140, EP-51, HS-436, Evinal-21, HV-124, drawing varnish UR-231 on printed boards, blocks and knots.
Shot blasting of metal surfaces of preparations, details, molding and other products.
The directional coupler: channel section: 23x10, is intended for separation of the channels of transmission of electromagnetic energy
Waveguide switch: channel section 23x10, designed for switching the channels of transmission of electromagnetic energy under the influence of control signals
Switch coaxial: designed for switching channels of transmission of electromagnetic energy under the influence of control signals
Waveguide-coaxial transition: cross sections of channels: 23х10 mm and 28.5 X12.6, mm is intended for connecting rectangular waveguides with coaxial cable
The section of the waveguide: the cross section of the channels: 7,2x3,4x1 mm 11x5. 5x0. 5 mm, mm 16x8, 17x8 mm, mm 23х10, 28,5x12,6 mm, 35х15 mm, 40х20 mm, 48х24 mm and length up to 1800 mm designed for transmission of electromagnetic energy upon inside the instrument and external connections
The section of the waveguide: the cross section of the channels: 7,2x3,4x1 mm 11x5. 5x0. 5 mm, mm 16x8, 17x8 mm, mm 23х10, 28,5x12,6 mm, 35х15 mm, 40х20 mm, 48х24 mm and length up to 1800 mm designed for transmission of electromagnetic energy upon inside the instrument and external connections
The section of the waveguide: the cross section of the channels: 7,2x3,4x1 mm 11x5. 5x0. 5 mm, mm 16x8, 17x8 mm, mm 23х10, 28,5x12,6 mm, 35х15 mm, 40х20 mm, 48х24 mm and length up to 1800 mm designed for transmission of electromagnetic energy upon inside the instrument and external connections
Sections brass curved waveguide: section channels: 7,2x3,4x1 mm 11x5. 5x0. 5 mm, mm 16x8, 17x8 mm, mm 23х10, 28,5x12,6 mm, 35х15 mm, 40х20 mm, mm 48х24 with different parameters of flexibility is designed to transmit electromagnetic energy at vnutripolostnyh and external connections.
Flexible waveguide section: channel sections: 16x8 mm, 17x8mm, 23x10 mm, 28.5x12.6 mm, 35x15 mm, 40x20 mm and length up to 120 mm, are intended for transmission of electromagnetic energy for intra-instrument and external connections
Detector section: channel cross-sections: 23x10 mm and 28.5x12.6 mm, designed to control the VSWR of the waveguide channel
Section of waveguide sealing with a union: sections of channels: 23x10 mm, 28.5x12.6 mm and 40x20 mm, is intended for sealing the channels of waveguide paths and supplying compressed air in them during drying
For all questions of placing orders, please call the phone numbers in the Contacts section